SHEV Compact Control Panel WSC 104, 4A

WSC 104 S 0101 E2 smoke and heat exhaust compact control unit, 4.0 A

New WindowMaster smoke and heat exhaust compact control unit WSC 104!

Smoke and heat exhaust control unit for controlling 24 VDC drives for the smoke exhaust function combined with daily ventilation.

The WSC 104 control unit is suitable for smaller buildings, such as staircase smoke extraction systems, sports halls, restaurants, etc.

Application area

  • Control of 1 VELUX® smoke and heat exhaust roof window (pitched roof) or up to 2 VELUX® roof access hatches CSJ (rooflight with spindle drive
  • for smoke and heat exhaust and daily ventilation
  • 1 smoke and heat exhaust group / 1 ventilation group
  • Control of window drives up to 4.0 A
  • Connection of ±24V standard drives, MotorLink® drives or compressed gas generators possible
  • Smoke extraction of smaller and medium-sized buildings
  • Configuration via DIP switch
  • less wiring effort thanks to bus technology
  • low power consumption
  • incl. 2 emergency batteries (12V, 3.4Ah, type WSA 003 0101)
  • Primary voltage: 230V AC, 50Hz (85-264V AC, 47-63Hz)
  • Secondary voltage: 24V DC (±15%)
  • Residual ripple (full load): 150mVss
  • Dimensions (W x H x D): 224 x 283 x 85mm (HxWxD)mm
  • Colour: RAL 9016 white


Performance features

  • Control of smoke exhaust combined with ventilation
  • built-in emergency power supply for min. 72 hours through battery backup
  • certified according to EN 12101-10 and ISO 21927-9
  • automatic stroke limitation and/or opening time of leaves and flaps during the ventilation function without additional modules
  • fire alarm system activation via potential-free contact without additional modules
  • configuration via 8 DIP switches
  • fault message via diagnostic LEDs
  • easy installation – less wiring effort
  • line monitoring of smoke and heat exhaust push button
  • line monitoring of smoke and heat exhaust detector (if used)
  • monitoring of the drive supply line
  • surface mounting


Connection options

  • 1 motor line for ±24V standard drives or MotorLink® drives or compressed gas generators
  • 1 input for ventilation push button
  • 1 input for smoke and heat exhaust control points
  • 1 input for smoke detector / heat differential detector
  • output for forwarding alarm signals
  • output for forwarding a fault message
  • input for wind/rain sensor (WLA 330 or WLA 331)
  • connection for USB devices
  • 8 DIP switches for easy configuration

Technical data
Flush mounting possible No
Maintenance timer No
Max. number of smoke detectors 10
Operating temperature -5 to +40°C
Output 4 A
Pressurized gas generator connectable Yes
  • Brand: WindowMaster 
    [Info]

    WindowMaster GmbH
    Friesenweg 32a
    22763 Hamburg
    T: +49 40 87409 560
    windowmaster.de
    vertrieb.de@windowmaster.com

  • Product Code: WindowMaster WSC 104 S 0101 E2
  • Availability: 2-3 Days

We are an official WindowMaster distribution partner.




Related Products

Rain and Wind Sensor WLA 330
WLA 330 0101

Rain and Wind Sensor WLA 330

394.94€ incl. 19% VAT plus shipping

Rain sensor WLA 331
WLA 331 0101

Rain sensor WLA 331

243.27€ incl. 19% VAT plus shipping

Replacement cylinder WSA 440
WSA 440 0101

Replacement cylinder WSA 440

35.41€ incl. 19% VAT plus shipping

Battery WSA 003, 12V, 3.4Ah
WSA 003 0101

Battery WSA 003, 12V, 3.4Ah

46.52€ incl. 19% VAT plus shipping

End module actuator WSA 514 0102
WSA 514 0102

End module actuator WSA 514 0102

10.23€ incl. 19% VAT plus shipping

Power Supply WCA 1P1 for WSC 104
WCA 1P1 0101

Power Supply WCA 1P1 for WSC 104

104.49€ incl. 19% VAT plus shipping